| model
PW2RAUD SPECS |
|
Made in the
USA
|
- 6 grounded 3-wire #14 SJT line cord, right angle plug
- Two grounded 15A outlets
- Magnetic shielding steel cabinet: Black
- Self-test circuit with visual indicator
- Weight: 5.75 lbs.
- Dimensions: 3.5H x 7.85W x 3.75D
|
|
Load
Ratings:
|
Model: 2RAUD 15A @ 120 volts, single phase, 50-60 Hz; full load regulation 1%.
|
|
Endurance
Test:
|
1,000 surges, 3,000 amperes, 6,000 volts,
SVR=330, actual Suppressed Voltage <280 Volts, no failures, L-N (ground wire protection) mode, U.S.
Govt. Mode 1).
|
|
Limiters:
|
Series surge reactor current limiter; cascaded, auto-tracking dual polarity voltage
limiters; dual pulse inverters. Parameters optimized for switch-mode power supply
protection.
|
|
Clamping
Voltage Onset:
|
172 volts nominal; 2 volts above peak line voltage (auto-tracking).
|
|
EMI/RFI
Filter response:
|
(bi-directional, wave tracking): With 50 ohm Rg load: 3db@5kHz;
26dB@100kHz; 38dB@300kHz.
|
|
Let-Through
Slew Rate:
|
5,000 volt/s disturbance reduced to 28v/s within AC power wave envelope, and
less than 10v/s outside the power wave envelope.
|
|
Snubber:
|
Instant reacting snubber for very fast-rising surges generated within the building.
|
Maximum
Applied Surge Pulse Joule Rating:
|
Unlimited rating (due to surge current limiting) (8x20s).
|
Maximum
Applied Surge Pulse Voltage:
|
6,000 volts (1.2 x 50s) (Industry Standard rating).
|
Maximum
Applied Surge Pulse Current:
|
>100,000 amperes (unlimited due to current limiting) (8 x 20s).
|
Endurance,
C62.41-1991
(formerly IEEE 587) Category B3 (C1) pulses (6kV,
3kA):
|
2kv>100,000; 4kv>10,000; 6kv>1,000
(NRTL verified).
|