Model PW8R15AUD - Series Mode Surge FilterS

The product comes with six switchable outlets and two additional fixed (always on) outlets.

All receptacles are isolated (preventing the cross talk between digital and analog components).
Specifications below.
model PW8r15AUD

  

Click Here To Order

   PW8R15AUD
view image
   15 amp, 8 receptacle (isolated) point of use unit for audio use. Outlets:8 (6 switched, ... ; Weight:5.25 lbs.; 
Dimensions (H x W x D): 3.9" x 8.3" x 4.0"
   $249.00
view discounts
 
Series 8R - Model 8R15 Specs 
Made in the USA
  • 6 grounded 3-wire #14 SJT line cord, right angle plug
  • Two unswitched grounded outlets
  • Six switched grounded outlets
  • Magnetic shielding steel cabinet: Black
  • Self-test circuit with visual indicator
  • Weight: 5.25 lbs.
  • Dimensions: 3.9H x 8.3W x 4.0D
Load Ratings:

 
Model PW8R15AUD 15 amps @120 volts, single phase, 50-60 Hz; full load regulation 1%.
Endurance Test: 1,000 surges, 3,000 amperes, SVR=330, actual Suppressed Voltage <300 Volts, no failures, L-N (ground wire protection) mode.
 
Receptacle Isolation*: Low pass filter isolation assures >40db load to load isolation for EFT bursts.

 
Limiters: Series surge reactor current limiter; cascaded, auto-tracking dual polarity voltage limiters; dual pulse inverters. Parameters optimized for switch-mode power supply protection.
 
Clamping Voltage Onset: 172 volts nominal; 2 volts above peak line voltage (auto-tracking).
 
EMI/RFI Filter response: (bi-directional, wave tracking): With 50 ohm Rg load: 3db@5kHz; 26dB@100kHz; 38dB@300kHz.
 
Let-Through Slew Rate: 5,000 volt/s disturbance reduced to 20v/s within AC power wave envelope, and less than 10v/s outside the power wave envelope.
 
Snubber: Instant reacting snubber for very fast-rising surges generated within the building.
 
Maximum Applied Surge Pulse Joule Rating:
  
Unlimited rating (due to surge current limiting) (8x20s).
Maximum Applied Surge Pulse Voltage: 6,000 volts (1.2 x 50s) (Industry Standard rating).

Maximum Applied Surge Pulse Current:
 
>100,000 amperes (unlimited due to current limiting) (8 x 20s).
Endurance, C62.41-1991 (formerly IEEE 587) Category B3 (C1) pulses: 2kv>100,000; 4kv>10,000; 6kv>1,000 (NRTL verification).